EN326

From Elektronisches Studio
Revision as of 17:42, 26 September 2017 by Dr admin (talk | contribs) (→‎Patchbay 1)
Jump to navigationJump to search

Overview

The engineering room EN326 holds the two workstation and matrix computers for EN324 and EN325. Additionally it is host to the computers used to render audio for the Wave Field Synthesis in the small studio.

All digital to analog and analog to digital conversion takes place in here.

Most signals can be patched using the patchbays.

The room is connected with the two studios, EN327 and EN328.

Rack

The 19" racks hold several patchbays, a MADI bridge, the wordclocks for both studios and their DACs.

As long as one of the power keys is turned to 1, the rack will have power.

Connections

EN326 - EN326

Multicore Signal path Signal From To Connector type in room Patchbay Row Connector Shield Hot (+) Cold (-)
M16 70 1 AK 1 IN 1 EN326 Connector box AK 1 EN326 Patchbay 7 XLRf Connector 7 1 1 gray white brown
2 AK 1 IN 2 7 1 2 gray white green
3 AK 1 IN 3 7 1 3 gray white yellow
4 AK 1 IN 4 7 1 4 gray white gray
5 AK 1 IN 5 7 1 5 gray white pink
6 AK 1 IN 6 7 1 6 gray white blue
7 AK 1 IN 7 7 1 7 gray white red
8 AK 1 IN 8 7 1 8 gray white black
9 AK 1 OUT 1 XLRm Connector 7 2 1 gray white violet
10 AK 1 OUT 2 7 2 2 gray white white/brown
11 AK 1 OUT 3 7 2 3 gray white white/green
12 AK 1 OUT 4 7 2 4 gray white white/yellow
13 AK 1 OUT 5 7 2 5 gray white white/gray
14 AK 1 OUT 6 7 2 6 gray white white/pink
15 AK 1 OUT 7 7 2 7 gray white white/blue
16 AK 1 OUT 8 7 2 8 gray white white/red
M16 71 1 AK 2 IN 1 EN326 connector box AK 2 EN326 Patchbay 7 XLRf Connector 7 1 9 gray white brown
2 AK 2 IN 2 7 1 10 gray white green
3 AK 2 IN 3 7 1 11 gray white yellow
4 AK 2 IN 4 7 1 12 gray white gray
5 AK 2 IN 5 7 1 13 gray white pink
6 AK 2 IN 6 7 1 14 gray white blue
7 AK 2 IN 7 7 1 15 gray white red
8 AK 2 IN 8 7 1 16 gray white black
9 AK 2 OUT 1 XLRm Connector 7 2 9 gray white violet
10 AK 2 OUT 2 7 2 10 gray white white/brown
11 AK 2 OUT 3 7 2 11 gray white white/green
12 AK 2 OUT 4 7 2 12 gray white white/yellow
13 AK 2 OUT 5 7 2 13 gray white white/gray
14 AK 2 OUT 6 7 2 14 gray white white/pink
15 AK 2 OUT 7 7 2 15 gray white white/blue
16 AK 2 OUT 8 7 2 16 gray white white/red

Patchbays

Several patchbays exist, creating easy access to the many multicore lines between the several rooms and gear in EN326.

Patchbay 1

Row 1 Row 2
Connector Connected by Signal Connector Connected by Signal
1 M8 11 EN324 RME Micstasy analog OUT 1 1
2 EN324 RME Micstasy analog OUT 2 2
3 EN324 RME Micstasy analog OUT 3 3
4 EN324 RME Micstasy analog OUT 4 4
5 EN324 RME Micstasy analog OUT 5 5
6 EN324 RME Micstasy analog OUT 6 6
7 EN324 RME Micstasy analog OUT 7 7
8 EN324 RME Micstasy analog OUT 8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 M8 12 EN324 DVD analog OUT 1 17 D-sub DB-25 1B DirectOut Andiamo IN 1
18 EN324 DVD analog OUT 2 18 1B DirectOut Andiamo IN 2
19 EN324 DVD analog OUT 3 19 1B DirectOut Andiamo IN 3
20 EN324 DVD analog OUT 4 20 1B DirectOut Andiamo IN 4
21 EN324 DVD analog OUT 5 21 1B DirectOut Andiamo IN 5
22 EN324 DVD analog OUT 6 22 1B DirectOut Andiamo IN 6
23 EN324 CD analog OUT 1 23 1B DirectOut Andiamo IN 7
24 EN324 CD analog OUT 2 24 1B DirectOut Andiamo IN 8
25 M16 15 EN324 AF1 IN 1 25 D-sub DB-25 1B DirectOut Andiamo IN 9
26 EN324 AF1 IN 2 26 1B DirectOut Andiamo IN 10
27 EN324 AF1 IN 3 27 1B DirectOut Andiamo IN 11
28 EN324 AF1 IN 4 28 1B DirectOut Andiamo IN 12
29 EN324 AF1 IN 5 29 1B DirectOut Andiamo IN 13
30 EN324 AF1 IN 6 30 1B DirectOut Andiamo IN 14
31 EN324 AF1 IN 7 31 1B DirectOut Andiamo IN 15
32 EN324 AF1 IN 8 32 1B DirectOut Andiamo IN 16
33 EN324 AF3 IN 1 33 D-sub DB-25 1B DirectOut Andiamo IN 17
34 EN324 AF3 IN 2 34 1B DirectOut Andiamo IN 18
35 EN324 AF3 IN 3 35 1B DirectOut Andiamo IN 19
36 EN324 AF3 IN 4 36 1B DirectOut Andiamo IN 20
37 EN324 AF3 IN 5 37 1B DirectOut Andiamo IN 21
38 EN324 AF3 IN 6 38 1B DirectOut Andiamo IN 22
39 EN324 AF3 IN 7 39 1B DirectOut Andiamo IN 23
40 EN324 AF3 IN 8 40 1B DirectOut Andiamo IN 24
41 M8 13 EN324 RME Fireface UFX analog OUT 1 41 D-sub DB-25 1B DirectOut Andiamo IN 25
42 EN324 RME Fireface UFX analog OUT 2 42 1B DirectOut Andiamo IN 26
43 EN324 RME Fireface UFX analog OUT 3 43 1B DirectOut Andiamo IN 27
44 EN324 RME Fireface UFX analog OUT 4 44 1B DirectOut Andiamo IN 28
45 EN324 RME Fireface UFX analog OUT 5 45 1B DirectOut Andiamo IN 29
46 EN324 RME Fireface UFX analog OUT 6 46 1B DirectOut Andiamo IN 30
47 EN324 RME Fireface UFX analog OUT 7 47 1B DirectOut Andiamo IN 31
48 EN324 RME Fireface UFX analog OUT 8 48 1B DirectOut Andiamo IN 32

Patchbay 2

Row 1 Row 2
Connector Connected by Signal Connector Connected by Signal
1 D-sub DB-25 1A RME M-16 DA OUT 1 1 M16 16 EN324 Meyer UPL-1 OUT 1
2 1A RME M-16 DA OUT 2 2 EN324 Meyer UPL-1 OUT 2
3 1A RME M-16 DA OUT 3 3 EN324 Meyer UPL-1 OUT 3
4 1A RME M-16 DA OUT 4 4 EN324 Meyer UPL-1 OUT 4
5 1A RME M-16 DA OUT 5 5 EN324 Meyer UPL-1 OUT 5
6 1A RME M-16 DA OUT 6 6 EN324 Meyer UPL-1 OUT 6
7 1A RME M-16 DA OUT 7 7 EN324 Meyer UPL-1 OUT 7
8 1A RME M-16 DA OUT 8 8 EN324 Meyer UPL-1 OUT 8
9 D-sub DB-25 1A RME M-16 DA OUT 9 9 EN324 Meyer UPL-1 OUT 9
10 1A RME M-16 DA OUT 10 10 EN324 Meyer UPL-1 OUT 10
11 1A RME M-16 DA OUT 11 11 EN324 Meyer UPL-1 OUT 11
12 1A RME M-16 DA OUT 12 12 EN324 Meyer UPL-1 OUT 12
13 1A RME M-16 DA OUT 13 13
14 1A RME M-16 DA OUT 14 14
15 1A RME M-16 DA OUT 15 15
16 1A RME M-16 DA OUT 16 16
17 D-sub DB-25 1B DirectOut Andiamo OUT 1 17 M8 17 EN324 AF6 OUT 1
18 1B DirectOut Andiamo OUT 2 18 EN324 AF6 OUT 2
19 1B DirectOut Andiamo OUT 3 19 EN324 AF6 OUT 3
20 1B DirectOut Andiamo OUT 4 20 EN324 AF6 OUT 4
21 1B DirectOut Andiamo OUT 5 21 EN324 AF6 OUT 5
22 1B DirectOut Andiamo OUT 6 22 EN324 AF6 OUT 6
23 1B DirectOut Andiamo OUT 7 23 EN324 AF6 OUT 7
24 1B DirectOut Andiamo OUT 8 24 EN324 AF6 OUT 8
25 D-sub DB-25 1B DirectOut Andiamo OUT 9 25 M16 18 EN324 AF2 OUT 1
26 1B DirectOut Andiamo OUT 10 26 EN324 AF2 OUT 2
27 1B DirectOut Andiamo OUT 11 27 EN324 AF2 OUT 3
28 1B DirectOut Andiamo OUT 12 28 EN324 AF2 OUT 4
29 1B DirectOut Andiamo OUT 13 29 EN324 AF2 OUT 5
30 1B DirectOut Andiamo OUT 14 30 EN324 AF2 OUT 6
31 1B DirectOut Andiamo OUT 15 31 EN324 AF2 OUT 7
32 1B DirectOut Andiamo OUT 16 32 EN324 AF2 OUT 8
33 D-sub DB-25 1B DirectOut Andiamo OUT 17 33 EN324 AF4 OUT 1
34 1B DirectOut Andiamo OUT 18 34 EN324 AF4 OUT 2
35 1B DirectOut Andiamo OUT 19 35 EN324 AF4 OUT 3
36 1B DirectOut Andiamo OUT 20 36 EN324 AF4 OUT 4
37 1B DirectOut Andiamo OUT 21 37 EN324 AF4 OUT 5
38 1B DirectOut Andiamo OUT 22 38 EN324 AF4 OUT 6
39 1B DirectOut Andiamo OUT 23 39 EN324 AF4 OUT 7
40 1B DirectOut Andiamo OUT 24 40 EN324 AF4 OUT 8
41 D-sub DB-25 1B DirectOut Andiamo OUT 25 41 M8 19 EN324 RME Fireface UFX analog IN 1
42 1B DirectOut Andiamo OUT 26 42 EN324 RME Fireface UFX analog IN 2
43 1B DirectOut Andiamo OUT 27 43 EN324 RME Fireface UFX analog IN 3
44 1B DirectOut Andiamo OUT 28 44 EN324 RME Fireface UFX analog IN 4
45 1B DirectOut Andiamo OUT 29 45 EN324 RME Fireface UFX analog IN 5
46 1B DirectOut Andiamo OUT 30 46 EN324 RME Fireface UFX analog IN 6
47 1B DirectOut Andiamo OUT 31 47 EN324 RME Fireface UFX analog IN 7
48 1B DirectOut Andiamo OUT 32 48 EN324 RME Fireface UFX analog IN 8

Patchbay 3

Patchbay 4

Patchbay 5

Patchbay 6

Patchbay 7